Renewable
Energy

Canovate Indirect Adiabatic (CAN-IAC)

• Hydrophilic coated adiabatic heat exchanger specially designed and highly efficient with adiabatic performance

• Water frost protection feature

• Ability to work without problems up to -25 ° C

• Water saving mode

• Tank system feature, as well as water saving feature

• Fresh air fans are working proportionally according to the need to provide full capacity under normal conditions, and energy savings are achieved.

• Fresh air fans can achieve full capacity cooling by operating only half the capacity of data center fans even in the worst case. By this way, the energy is saved.

• Water hardness value measurement and water discharge

• One-piece assembly

• No screws are used on the device covers and the ability to easily service from each cover

• Proportional use of nozzle feed water depending on the outside temperature and humidity

• A design in itself, including each part of the monoblock and DX cell

• The energy efficiency rate goes over 30’s. (EER> 30)

• PUE <1.05 high efficiency energy saving

• Communication within the devices, teamwork compatibility and ability to

  • Cooling
  • A ++ Energy

Canovate Indirect Adiabatic (CAN-IAC)

Cooling Capacity (up to 50- 250 kW)

High Performance

EC Fan Technology

High Technology

Precise Temperature Control

Environmentally Friendly

Screwless Design

High Water Saving

Intelligent Control Mechanism

Modular Structure

High Energy Saving

Easy Service

Wide Range of Alternative Options

2 Years Warranty

ICERA CAN-IAC
  Process Temp. °C °C 36-22 36-24 37-25 40-25 42-27
DT K 14 12 12 15 15
CAN-IAC50
Cooling Capacity
30-75 kw
Process Air Flow m3/h 7.000 10.500 12.500 12.500 15.500
Adiabatic Cooling kW 30 41 50 60 75
Pressure Drop Pa 146/156 219/250 262/309 265/311 330/407
Water Consumption kg/h 52,9 74,9 89,4 99,2 124
Trim Cooling kW 0% - 100% max. 50 - -
Dimension (WxHxL) cm 200x280x500
CAN-IAC100
Cooling Capacity 60-150 kw
Process Air Flow m3/h 14.000 21.000 25.300 25.300 28.000
Adiabatic Cooling kw 60 80 100 120 140
Pressure Drop Pa 146/156 219/250 262/309 265/311 330/407
Water Consumption kg/h 106 150 180 188 254
Trim Cooling kW 0% - 80% max 80 - -
Dimension (WxHxL) cm 400x280x500
CAN-IAC150
Cooling Capacity
90-220 kw
Process Air Flow m3/h 19.000 29.800 37.300 39.800 43.800
Adiabatic Cooling kw 90 120 150 200 220
Pressure Drop Pa 146/156 219/250 262/309 265/311 330/407
Water Consumption kg/h 125 181 231 286 327
Trim Cooling kW 0% - 80% max 120 - -
Dimension (WxHxL) cm 570x385x350
CAN-IAC200
Cooling Capacity
120-300 kw
Process Air Flow m3/h 29.000 42.500 51.000 51.000 55.000
Adiabatic Cooling kW 120 160 200 240 280
Pressure Drop Pa 146/156 219/250 262/309 265/311 330/407
Water Consumption kg/h 210 274 341 380 403
Trim Cooling kW 0% - 80% max 160 - -
Dimension (WxHxL) cm 710x385x350
CAN-IAC250
Cooling Capacity
150-375 kw
Process Air Flow m3/h 36.000 50.000 63.500 63.500 65.000
Adiabatic Cooling kW 150 200 250 300 340
Pressure Drop Pa 146/156 219/250 262/309 265/311 277/329
Water Consumption kg/h 263 343 389 421 489
Trim Cooling kW 0% - 80% max 200 - -
Dimension (WxHxL) cm 850x385x350